Lightning & Surge Protection

Quick Enquiry

TYPE 1 / CLASS I

HS50-50i and HS50-50i LED are the lightning current arresters type 1 & class 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building.

View Details Write Review

TYPE 1 / CLASS I

HS100i is the lightning current arrester type 1 & class 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Zones Concept at the boundaries of LPZ 0 - 1 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building.

View Details Write Review

TYPE 1+2 / CLASS I+II

PIVM7-320/1+1 V series is a two-pole, metal oxide varistor lightning current and surge arrester, combined with gas discharge tube Type 1+2 & Class I+II according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305 ed.2), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge

View Details Write Review

TYPE 1+2 / CLASS I+II

PIVM7-320/3+1 Vseries is a four-pole, metal oxide varistor lightning current and surge arrester, combined with gas discharge tube Type 1+2 & Class I+II according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305 ed.2), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building

View Details Write Review

KO*G

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby.

View Details Write Review

KO*P

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby. Hakel company offers a wide range of coaxial protectors for various connector types and transmission power grades enabling usage in many applications. These coaxial protectors are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305.

View Details Write Review

KO-9P

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby. Hakel company offers a wide range of coaxial protectors for various connector types and transmission power grades enabling usage in many applications. These coaxial protectors are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305.

View Details Write Review

KO-10P

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby. Hakel company offers a wide range of coaxial protectors for various connector types and transmission power grades enabling usage in many applications. These coaxial protectors are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305.

View Details Write Review

KO-5GN

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby. Hakel company offers a wide range of coaxial protectors for various connector types and transmission power grades enabling usage in many applications. These coaxial protectors are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305.

View Details Write Review

KO-6GN

KO* is an innovated coaxial high-frequency protection range designed for protection of equipment connected to an aerial system by means of coaxial cables. Special gas discharge tubes with maximum discharge current Imax (8/20) = 10kA (or 20 kA in case of KO-5GN) ensure a reliable protection of the receiving and transmitting systems even against a lightning stroke nearby. Hakel company offers a wide range of coaxial protectors for various connector types and transmission power grades enabling usage in many applications. These coaxial protectors are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305.

View Details Write Review

TYPE 2 / CLASS II

PIIIM-320/1+1 V series is a two-pole, metal oxide varistor surge arrester combined with gas discharge tube, Type 2 & Class II according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of the switching overvoltage, which is generated in power supply systems entering the building.

View Details Write Review

TYPE 2 / CLASS II

PIIIM-320/3+1 V series is a four-pole, metal oxide varistor surge arrester combined with gas discharge tube, Type 2 & Class II according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of the switching overvoltage, which is generated in power supply systems entering the building. The main use of PIIIM-320/3+1 V series arrester is in all kinds of industry, residential and administration buildings.

View Details Write Review

TYPE 2 / CLASS II

PIIIM-320/3+0 V series is a three-pole, metal oxide varistor surge arrester Type 2 & Class II according to EN 61643-11 and IEC 61643-1. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of the switching overvoltage, which is generated in power supply systems entering the building. The main use of PIIIM-320/3+0 Vseries arrester is in all kinds of industry, residential and administration buildings.

View Details Write Review

TYPE 3 / CLASS III / DC

P-k16*DC is designed for protection of electronic appliances in L.V. power supply DC systems against the impulse surge effects. They are constructed for mounting on DIN rail 36mm for rated load currents 16A according to IEC 61643-1, EN 61643-11 and EN 62305 standards (arrester class III - 3rd stage protection). Right function of the in-built protective elements, MOV varistors, is signalized by green light on the front panel of the equipment.

View Details Write Review

TYPE 3 / CLASS III

P-k16*AC is designed for protection of electronic appliances in L.V. power supply AC systems against the impulse surge effects. They are constructed for mounting on DIN rail 36mm for rated load currents 16A according to IEC 61643-1, EN 61643-11 and EN 62305 standards (arrester class III - 3rd stage protection). Right function of the in-built protective elements, MOV varistors, is signalized by green light on the front panel of the equipment.

View Details Write Review

TYPE 3 / CLASS III

ZS-1I, ZS-1P are the surge arresters type 3 & Class III according to EN 61643-11 and IEC 61643-1 and IEC 61643-1 designed for installation into electrical installation systems, e.g.: cable ducts and flush-mounted sockets as an additional protection. These devices are suitable supplements of socket distribution which are protected by PI-k protector. The right function of ZS-1I type is indicated by green LED diode. When the indicator is dark, the device must be replaced or technically checked. ZS-1P contains an acoustic fault indicator (buzzer).

View Details Write Review

TYPE 3 / CLASS III

PI-k8 is a single-phase surge arrester type 3 & Class III, which is equipped with high-frequency filter, according to EN 61643-11 and IEC 61643-1. It is intended for use in the power supply lines, which are operated as TN-S system. The arrester PI-k8 is constructed for mounting on DIN rail 35mm and designed for protection of single-phase electronic appliances in L.V. power supply systems against the transient surge and high-frequency disturbance.

View Details Write Review

TYPE 2 + 3 / CLASS II+III

ZS-1 275 DS RS and ZS-1 275 DS DI are surge arresters Type 2+3 & Class II + III (TYPE 3 protects the device only to 5m lead) according to EN 61643-11 and EN 62305 designed for LED lighting protection for installations largely e.g. in tunnels, properties and premises, street lights etc.

View Details Write Review

HT-NET PoE 6cat X series

These surge protection devices intended for computer networks are specially designed for securing a faultless data transfer within computer networks category 6. They protect input electronic circuits of network cards against damage caused by surge effects in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 according to EN 62305.

View Details Write Review

HT-TEL X series

Hakel Transmition-TEL is designed to protect telecommunications equipment. The casing of this protector is made out of light alloy, which ensures high mechanical and thermal resistance. Imax = 2 kA. It is recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2-3 according to EN 62305.

View Details Write Review

HT-CCTV 6 X series

Hakel Transmition-CCTV is designed to protect video transmission equipment, which process the transferred video signal. The casing of this protector is made out of light alloy, which ensures high mechanical and thermal resistance. Imax= 5 kA. It is recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2-3 according to EN 62305.

View Details Write Review

TYPE 3 / CLASS III

PI-3k is a three-phase surge arrester type 3 & Class III, which is equipped with high-frequency filter, according to EN 61643-11 and IEC 61643-1. It is intended for use in the power supply lines, which are operated as TN-S system. PI-3k120 is designed for protection of three-phase electronic appliances in L.V. power supply systems against the transient overvoltage and high-frequency disturbance.

View Details Write Review

HGS100

HGS100 and HGS100 EB are a separating high power gas discharge tubes intended for equipotential bonding of an installation parts of buildings, which are not interconnected. In case of origin of p.d. (potential diference) between those parts, the high power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 is 0,001 ÷ 0,002 ?)

View Details Write Review

HGS100 Ex

HGS100 Ex - Separating high power gas discharge tube HGS100 Ex for use in explosion hazards areas. It is intended for equipotential bonding of the installation parts of buildings or technological entities which are not interconnected operationaly. In case of p.d. (potential difference) origin between those parts, the high power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 Ex is 0,001÷ 0,002?).

View Details Write Review

HGS100 EB

HGS100 and HGS100 EB are a separating high power gas discharge tubes intended for equipotential bonding of an installation parts of buildings, which are not interconnected. In case of origin of p.d. (potential diference) between those parts, the high power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 is 0,001 ÷ 0,002 ?)

View Details Write Review

CONTACT

For any kind of query, contact us with the details below.

  • Mr. Anurag Gupta
  • +91 - 9650044992
  • sales4@alliedpowersolutions.com
  • Allied Power Solutions
    T- 4,5 & 6 , Third Floor Pankaj Plaza – 3, I.P Extn., Patparganj
    New Delhi - Delhi (India.) - 110092

Leave a message

Please fill in your info and we will contact you soon.